Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • National logistician can move equipment to any other location in the country

  • 4
    #TitleUser StoryLabelImportanceNotesJIRA Tickets
    1

    Add & Delete facility CCE inventory

    As a DIVO, I need to select equipment from the existing CCE catalog so that I can create a list of specific CCE at each facility.

    Acceptance criteria:

    • user selects Make
    • user selects Model
    • remainder of fields appears below (see "Add specific equipment info..." story)

    MVP[SELV/SIIL] CCE: Add/Delete CCE in Facility Equipment List
    2

    Add specific equipment info to facility CCE inventory

    As a DIVO, I need to add device-specific information for each piece of CCE so that I can have a full record of each CCE at the facility

    1. The following fields can be updated:
       

      • Serial Number

    2. Model # / Name
      • Installation / Commission date
      • Unique identifier (optional) - (CCE name within facility, e.g. "Fridge 1." Can be a text field.)
      • Barcode?
      • Year of warranty expiry (if applicable)
      • Does it have associated Stabilizer (req)  - Yes / No

      • Does it have associated manual temp gauge - Yes / No
      • Status (req) - defaults to Functional

      • Facility (move the equipment to a different facility)

      • Active - Yes / No


    3. There is not a need to track what facility equipment used to be located (only current location is needed)
      • (include decommission date?) (addressed by functionality status: decommissioned)

      • Additional notes (text area)


    MVP

    List of fields needs to be in agreement with maintenance needs



    Image Added









    3View CCE inventory list
    1. National cold chain manager can see/view a list of all CCE equipment in the country (including national store), with ability to filter or sort this list by Region and District

    2. There is not a need to track what facility equipment used to be located (only current location is needed)

    3. National logistician can move equipment to any other location in the country

    4. RIVO can see/view a list of all CCE equipment in the Region (All DVS and All HFs) including Regional Vaccine Store, with ability to filter or sort this list by District

    5. DIVO can see/view a list of all CCE equipment in their district (All Health Facilities that are in that particular district) including at the District vaccine Store

    MVPList of fields needs to be in agreement with maintenance needs
    3MVP?

    ADDED POST-COPENHAGEN

    Do we need a feature where someone (EPI mgr, DIVO) can "move" (/re-register) CCE device at a different facility?


    4Require fieldsAs an EPI Manager/system admin, I want to require certain fields that a DIVO must fill out when they are entering information about their CCE inventory so that I can ensure all of the needed information is recorded appropriately within the system.
    Next

    0 votes

    Discussion was tha for the time being (MVP)  this can be customized for an implementation if needed.


    5Include warranty info

    As a CCE technician, I want to see whether a device is under warranty so that I can take the correct steps for repair.

    As a DIVO, I want to refer to which of my devices is under warranty so that I can take the appropriate steps for arranging replacement, if necessary.

    Acceptance criteria:

    • It is possible to just include this information as a text field where the person entering the information can write "April 2018", etc.

    Next8 votes
    56Include warranty contact infoAs a CCE technician, I want to see who I should call for broken CC equipment under warranty so that I can solicit the support I need for repairs.
    Next3 votes
    67Configure "edit equipment info" page

    As the system administrator, I need to determine which pieces of device-specific information will be required for each CCE added at the facility level so that a detailed CCE record is created for each facility.

    Acceptance criteria:

    • Pulls from a global set of fields agreed upon by stakeholders

    • The following fields could be included:

      • Serial Number (req?)

      • Year of Installation (req) - must be 4 digit year

      • Stabilizer (req)  - Yes / No

      • Status (req) - defaults to Functional

      • Facility (move the equipment to a different facility)

      • Active - Yes / No


    Next0 votes
    78Add related CCE equipment

    As a DIVO, I want to make note of which related equipment (voltage stabilizer, temperature monitor) is associated with each CCE device in a facility list so that I can see the full picture of how my CCE devices are being supported.

    Acceptance criteria:

    • Does not need to list specific make/models
    • Can be "voltage stabilizer yes/no"

    Next2 votes
    89Bulk additions/deletionsAs an EPI Manager, I want to bulk add/delete CCE equipment from facility inventory lists so I can easily adjust the inventories when decisions are made about starting to use or no longer using a specific make/model.
    Next

    0 votes

    Not a lot of discussion around this feature. Will need to engage with stakeholders to further understand. (Even user story was fleshed out from very stubby stub.)


    910Sort CCE by typeAs an EPI manager, I want a query function to sort all CCE in a specific area by type so that I can see at a glance where specific make/models of CCE are located within the country.
    Next0 votes

    ...


    QuestionOutcome
    1

    National logistician can move equipment to any other location in the country.

    Need to figure out what scenarios that need to be supported.


    2We don't have a story for "view cce inventory list." The need for an inventory report was discussed, but it seems to follow that a screen view with a query-able list of CCE devices for the DIVO to see at a glance what is working and isn't. We have a story for EPI Manager above, but I think the filterable/query-able view of devices at a CCE (along with their functionality status) needs to be addressed. This is captured in the VIMS story "Search inventory" https://openlmis.atlassian.net/wiki/pages/resumedraft.action?draftId=112585116&draftShareId=54816cd3-5685-4baf-9caa-17c897e11228
    3Do we need to be able to move a CCE device from facility to facility without re-registering it from scratch?

    Out of Scope

    Out of scope for this feature OR potentially saving for future development.

    ...