#TitleUser StoryLabelImportanceNotes
1Input Temperature and  Functionality Status manually

As a HW or logistician at a facility, I want to input the temperature and corresponding functionality status of the facility CCE so that:

  • Upstream SC personnel are aware of the status so that they can prepare the resupply order for pick-up or delivery
  • Upstream CCE maintenance personnel are aware of the status so that they can plan for repairs or replacement



SELV/SIILMust Have
  • Additional considerations or noteworthy references (links, issues)
2Generate functionality status from RTM devices

As a sub-national store manager, I want to see the functional status of a CCE from RTM devices so that I can plan the pick-up or delivery order

 

As a CCE maintenance planner, I want to see the functional status of a CCE from RTM devices so that I can plan the schedule for repair or replacement
RTM; Nexleaf; ColdTraceNice to Have
3Input reasons for failure or improper function manually

As a HW or logistician at a facility, I want to input the reason for improper functionality of the facility CCE so that:

  • Upstream CCE maintenance personnel are aware of the reason so that they know what to plan for in terms of repairs
  • Upstream EPI policy manager are aware of which CCE needs replacement or type of CCE works well
SELV/SIILMust have
4Generate notifications depending on functionality

As a HW at a facility, I want to know when a CCE is no longer working properly so that I can move the products stored within it

As a HW at a facility, I want to send a notification to the system when a CCE is no longer working properly so that upstream managers can take corrective action

As an upstream CCE personnel, I want to know when a CCE is no longer working properly so that I can plan a repair or replacement schedule

As an upstream store manager, I want to know when a CCE is no longer working properly so that I can plan the upcoming order for that store accordingly

As an upstream logistician, I want to know when a CCE is no longer working properly so that I can plan the upcoming distribution schedule for that facility accordingly

SELV/SIILMust have

Diagrams


Dependencies

DescriptionLink
All other CCE product reqsLink to JIRA

Open Questions

Below is a list of questions to be addressed as a result of this requirements document:

#QuestionOutcomeStatus
1

What falls under the category of equipment? Refrigerators/passive storage devices such as cold boxes/freezers/walk-in cold rooms?

Communicate the decision reached Open, In Progress, Closed, and date of closure
2

This requirement says the system should report functionality – how much of the reporting comes from someone inputing “yes working/not working/maybe working” versus an automatic report that pulls data from temperature logs coming into the system via RTM, fridge log tags, or daily written logs? That is, which one takes precedence if both options available?



3Is another requirement needed to be written up for inputing data from daily logs (either on paper or on the fridge tag) or does the user story #1 in this requirement capture the need?