Comment: Updated tablet instructions to include turning browser on/off

A few issues have been noted when trying to perform a SELV upgrade:

  • Tablet’s MAY need the user to manually clear the cache.  This behavior has been sporadic.  Another solution MAY be simply closing the browser (restart tablet for good measure) and trying again.  The tablet did display the “Downloading Application Cache” modal dialog and seemed to work, but failed when it was brought off-line.  Users can clear the cache by going to the settings, privacy, clear history and clearing everything.
  • Mac and PC should refresh their browser when they get to the Manage Distributions screen, and the user should see the modal dialog box with a successfully application cache download message.  PC’s sometimes don’t report the cache being updated, but seem to update anyways.  The test for this should be to initiate a distribution that has never been initiated before, goto Record Data for a facility, click on EPI Inventory and see if BCG Diluent is present.  If it is the cache should be working, though an off-line test was not performed.
  • If a user upgrades and has a distribution cached from the previous version, if they then try to enter data for any facility and go to sync it, it will not come back with an error but will come back and say the facility is already synced (or rather not say much of anything but the color code indicates this).  We should ensure that everyone syncs and deletes their cached distribution before the upgrade and then re-initiates after the upgrade is made.

...